Features & Benefits
ZERO lead
Product made of lead-free brass (<0.1% lead content).
Thermometer
For easy maintenance.
Technical Information
Application:
Domestic hot water systems.
Functions:
Stepless temperature setting
Shut-off
Temperature control
Dimensions:
DN 15-20
Pressure class:
PN 16
Static pressure:
Max. static pressure during temperature control 10 bar.
Temperature:
Max. working temperature: 90°C
Temperature range:
35-80°C (WRAS approved up to 65°C)
Pre-set at 55°C
Kv at pre-set temperature: 0,3
Material:
Valve body: Brass CC768S
Valve plug: Corrosion-resistant acetal plastic
Seat: Corrosion-resistant polysulphone plastic
Other parts in contact with water: Brass CW724R (CuZn21Si3P)
O-rings: EPDM rubber
Handwheel: Glassfibre reinforced polyamide plastic
Marking:
Valve body: TA, ZERO, PN 16, DN, DR, flow direction arrow.
Handwheel: IMI TA and WaterMark logo
Approvals:
WaterMark, IAPMO R&T OCEANA
Articles
With thermometer
![](https://assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Drawings/TA-Therm_ZERO/With_M/52_820-015_M.gif)
Pre-set at 55°C
DN | D | L | H* | Kvnom | Kvs | Kg | Article No |
---|---|---|---|---|---|---|---|
15 | G1/2 | 86 | 90 | 0,30 | 1,1 | 0,45 | 52 820-915 |
20 | G3/4 | 92 | 90 | 0,30 | 1,1 | 0,50 | 52 820-920 |
*) Maximum height
TA-Therm is prepared for the compression coupling KOMBI. See catalogue leaflet KOMBI.
*) Maximum height
TA-Therm is prepared for the compression coupling KOMBI. See catalogue leaflet KOMBI.
*) Maximum height
TA-Therm is prepared for the compression coupling KOMBI. See catalogue leaflet KOMBI.
0-100°C
0-100°C
Thermometer
0-100°C
ØD | EAN | Article No |
---|---|---|
41 | 5902276805028 | 50 205-003 |
Photos
![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_pt-port_Persp.gif?itok=W1fMPpbs)
TA-Therm_ZERO_w_pt-port_Persp
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_thermometer_kat.gif?itok=3GnlbtAj)
TA-Therm_ZERO_w_thermometer_kat
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_AU/TA-Therm_ZERO_w_thermometer_WM.gif?itok=qWOAGL2Q)
TA-Therm_ZERO_w_thermometer_WM
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/Thermometer_TA-Therm_ZERO.gif?itok=Sqyadn0R)
Thermometer_TA-Therm_ZERO
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_thermometer_w_ZERO-logo.gif?itok=KGEH6mrD)
TA-Therm_ZERO_w_thermometer_w_ZERO-logo
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_thermometer_Front.gif?itok=1x2Q4oXF)
TA-Therm_ZERO_w_thermometer_Front
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w-o_thermometer_Persp.gif?itok=s20n-QGx)
TA-Therm_ZERO_w-o_thermometer_Persp
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w-o_thermometer_Front.gif?itok=x9ZibMmM)
TA-Therm_ZERO_w-o_thermometer_Front
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_thermometer_Persp.gif?itok=6inM6wKO)
TA-Therm_ZERO_w_thermometer_Persp
Select a format Download![](/sites/default/files/styles/large/https/assets.imi-hydronic.com/Pictures/Image_Gallery_Heimeier/Photos/TA-Therm_ZERO/TA-Therm_ZERO_w_pt-port_Front.gif?itok=jXBcNrG1)